In terms of low-grade heat energy recovery, It also has significant economic benefits. In recent years, plate heat exchangers have replaced traditional shell-and-tube heat exchangers in airports, hotels, and commercial buildings, and have achieved good results.8mm. Plates. Today, when high efficiency, environmental protection, and energy saving are exaggerated, plate heat exchangers have increasingly obvious advantages in the field of heat exchange. In addition to the volume of the equipment itself, no additional space for inspection and installation is required.

Clean the pipes connected to it before installation to prevent sand, oil, welding slag and other debris from entering the plate heat exchanger, causing blockage or damage to the flow channel. They can be used in various processes such as heating, cooling and food disinfection. The plate heat exchanger has a low fouling coefficient, and the fluid rolls violently between the plates to form turbulent flow.6-0. A certain inspection site should be reserved around the place where the plate heat exchanger is installed.Because the plate heat exchanger works for a long time, the surface of the heat transfer plate will produce different degrees of dirt or deposits, so we need to clean it.   When starting up, first open the low-pressure side medium plunger valve, and slowly open the high-pressure side medium plunger valve after the medium fills the plate heat exchanger channels.  

4. After the cleaning is completed, we need to debug it to ensure the normal use of the product.   5.  3, the sequence of opening and stopping of the plate heat exchanger   When stopping, first close the high-pressure side medium solenoid valve, and then close the low-pressure side medium solenoid valve. The plate heat exchanger occupies a small area and is light in weight. If there are often large particles of mud or debris in the medium, the supporting decontamination device produced by our factory should be equipped in front of the plate heat exchanger.

Check whether all clamping bolts are loose before putting it into use, and tighten if any. Then What are FHC310 Heat Exchangers Exporters the matters needing attention in the debugging process? Let’s follow the plate heat exchanger manufacturer to learn about it~  1.  2. The thickness of the plate used for heat exchange is only 0. The excellent plate design avoids the existence of dead zones, making it difficult for impurities to deposit and block in the channels, ensuring a good heat exchange effect.

https://www.forwon.com/product/fhc310.html

コメント